Beta /4 1000 0.74 litersGamma /L 1000 0.74 litersGamma /W 1000 0.74/69 liters Bag no.: 792026

Advertising [Product3rdColumn]
You might also like
Can easily be replaced without tools. Check the type and pump capacity of the pump.Note the arrow direction that indicates the flow direction on the valve As a flocculation pump, a peristaltic pump is more suitable, for example DF4a. See accessories. If the pump is not performing optimally, it may be because there is dirt in either the pressure or suction valve. This can be remedied in the following way:Disconnect the power.Unscrew the hose union nut and then remove both pressure/suction valves. Remember gloves and goggles !Rinse the valves thoroughly in water.Then try to blow through the valve against the direction of the arrow.You should not be able to blow through in that direction; if you can, the valve is defective.